Search results for "Elastic recoil"
showing 10 items of 43 documents
Evolution of the microstructure of sputter deposited TaAlON thin films with increasing oxygen partial pressure
2021
Abstract Recently, quaternary oxynitrides of transition metals and aluminum have attracted increasing interest due to their tunable properties. Within the present work, a series of TaAl(O)N films was sputter deposited using constant nitrogen and varying oxygen partial pressures. The films were grown from single element Ta and Al targets. The deposition parameters were adjusted to obtain a Ta/Al atomic ratio of ~50/50 for the oxygen-free film and were held constant for the following depositions, with the exception of the increasing oxygen partial pressure and compensatory decreasing argon partial pressure. Elastic recoil detection analysis revealed oxygen contents of up to ~26 at.%, while th…
Evaluation and Comparison of Novel Precursors for Atomic Layer Deposition of Nb2O5 Thin Films
2012
Atomic layer deposition (ALD) of Nb2O5 thin films was studied using three novel precursors, namely, tBuN═Nb(NEt2)3, tBuN═Nb(NMeEt)3, and tamylN═Nb(OtBu)3. These precursors are liquid at room temperature, present good volatility, and are reactive toward both water and ozone as the oxygen sources. The deposition temperature was varied from 150 to 375 °C. ALD-type saturative growth modes were confirmed at 275 °C for tBuN═Nb(NEt2)3 and tBuN═Nb(NMeEt)3 together with both oxygen sources. Constant growth rate was observed between a temperature regions of 150 and 325 °C. By contrast, amylN═Nb(OtBu)3 exhibited limited thermal stability and thus a saturative growth mode was not achieved. All films we…
Atomic Layer Deposition of LiF Thin Films from Lithd, Mg(thd)2, and TiF4 Precursors
2013
Lithium fluoride is an interesting material because of its low refractive index and large band gap. Previously LiF thin films have been deposited mostly by physical methods. In this study a new way of depositing thin films of LiF using atomic layer deposition (ALD) is presented. Mg(thd)2, TiF4 and Lithd were used as precursors, and they produced crystalline LiF at a temperature range of 300–350 °C. The films were studied by UV–vis spectrometry, field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), atomic force microscopy (AFM), time-of-flight elastic recoil detection analysis (ToF-ERDA), and energy dispersive X-ray spectroscopy (EDX). In addition, film adhesion was t…
Conceptual study of a heavy-ion-ERDA spectrometer for energies below 6 MeV
2017
Abstract Elastic recoil detection analysis (ERDA) is a well established technique and it offers unique capabilities in thin film analysis. Simultaneous detection and depth profiling of all elements, including hydrogen, is possible only with time-of-flight ERDA. Bragg ionization chambers or Δ E - E detectors can also be used to identify the recoiling element if sufficiently high energies are used. The chief limitations of time-of-flight ERDA are the beam induced sample damage and the requirement of a relatively large accelerator. In this paper we propose a detector setup, which could be used with 3 MeV to 6 MeV medium heavy beams from either a single ended accelerator (40Ar) or from a tandem…
Analysis of thin high-k and silicide films by means of heavy ion time-of-flight forward-scattering spectrometry
2006
The use of forward scattered heavy incident ions in combination with a time-of-flight-energy telescope provides a powerful tool for the analysis of very thin (5–30 nm) films. This is because of greater stopping powers and better detector energy resolution for heavier ions than in conventional He-RBS. Because of the forward scattering angle, the sensitivity is greatly enhanced, thus reducing the ion beam induced desorption during the analysis of very thin films. The drawback of forward scattering angle is the limited mass separation for target elements. We demonstrate the performance of the technique with the analysis of 25 nm thick NiSi films and atomic layer deposited 6 nm thick HfxSiyOz f…
Mass calibration of the energy axis in ToF- E elastic recoil detection analysis
2016
We report on procedures that we have developed to mass-calibrate the energy axis of ToF-E histograms in elastic recoil detection analysis. The obtained calibration parameters allow one to transform the ToF-E histogram into a calibrated ToF-M histogram.
Oxy-nitrides characterization with a new ERD-TOF system
2017
Abstract A new time-of-flight (TOF) camera was installed on Elastic Recoil Detection (ERD) measurement setup on the Tandem Accelerator at Universite de Montreal. The camera consists of two timing detectors, developed and built by the Jyvaskyla group, that use a thin carbon foil and microchannel plates (MCP) to produce the start and stop signals. The position of the first detector is fixed at 18 cm from the target, while the position of the second detector can be varied between 50 and 90 cm from the first detector. This allows to increase time resolution by increasing the distance between the time-of-flight detectors or to increase solid angle by decreasing the distance. Moving the detector …
Muscle-tendon interaction and elastic energy usage in human walking
2005
The present study was designed to explore how the interaction between the fascicles and tendinous tissues is involved in storage and utilization of elastic energy during human walking. Eight male subjects walked with a natural cadence (1.4 ± 0.1 m/s) on a 10-m-long force plate system. In vivo techniques were employed to record the Achilles tendon force and to scan real-time fascicle lengths for two muscles (medial gastrocnemius and soleus). The results showed that tendinous tissues of both medial gastrocnemius and soleus muscles lengthened slowly throughout the single-stance phase and then recoiled rapidly close to the end of the ground contact. However, the fascicle length changes demonstr…
Effects of different dropping intensities on fascicle and tendinous tissue behavior during stretch-shortening cycle exercise.
2003
This study examined whether the elasticity of the tendinous tissues plays an important role in human locomotion by improving the power output and efficiency of skeletal muscle. Ten subjects performed one-leg drop jumps (DJ) from different dropping heights with a constant rebound height. The fascicle length of the vastus lateralis muscle was measured by using real-time ultrasonography during DJ. In the braking phase of the DJ, fascicle lengthening decreased and the tendinous tissue lengthening increased with increased dropping intensity. In the subsequent push-off phase, the shortening of tendinous tissues increased with higher dropping intensity. The averaged electromyographic activities of…
Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents.
1993
AbstractObjectives. The purpose of this study was to measure elastic recoil from sequential angiograms after balloon angioplasty and after implantation of a balloon-expandable Palmaz-Schatz stent in the same patient, and to compare the results with the late angiographic outcome.Background. The immediate result of coronary balloon angioplasty is influenced by plastic deformation, primarily of the atherosclerotic plaque, and by elastic recoil, primarily of the less or nondiseased vessel circumference,Methods. The extent of elastic recoil was measured quantitatively as the difference between maximal balloon size and the resulting vessel diameter or cross-sectional area.Results. Analysis was pe…